Thermal & Optical Bi-spectrum Network Bullet Camera

Thermal & Optical Bi-spectrum Network Bullet Camera
Details:
Thermal & Optical Bi-spectrum Network Bullet Camera Product Description Automatic thermometer camera is also called infrared human body surface temperature quick test camera. It uses the infrared radiation principle to measure the human body temperature at one meter distance, and through the...
Send Inquiry
Description
Send Inquiry

Thermal & Optical Bi-spectrum Network Bullet Camera

Thermometer cameras

Thermometer camera 8-Anxia

Product Description

Automatic thermometer camera is also called infrared human body surface temperature quick test camera. It uses the infrared radiation principle to measure the human body temperature at one meter distance, and through the AI analysis, carries on the automatic temperature compensation and the calibration, realizes the automatic, fast temperature measurement and high body temperature alarm. The device is mainly used for the temperature screening in public places to prevents virus, as stations, airports, shopping malls, schools, companies, factories etc.

Thermometer camera system

Function Introduction

  1. Body temperature auto display on device, test speed 1-2 seconds per person

  2. When the body temperature is detected to be reach 37.4 °C, the device automatic alarms with sound and flash light

  3. Power on and work, with Wi-Fi hot-spot, the image and temperature will be directly displayed by the smart mobile phone APP and Laptop computer software

  4. IP Network management, real-time image and temperature display on the center platform

  5. Working mode: standard mode, fast mode, calibration mode

  6. HD visual image: HD1080P camera

  7. 1024 temperature zones infrared thermopile sensor by Heimann

Thermometer camera software 2

Specifications


Test Distance

1 meter

Lab Test Errors range

33°C to 37°C : error ±0.4°C
below 33°C, over 37°C : error ±0.6°C

Calibration

computer software, black body

Temperature Display

calibration mode:LED always on standard mode:LED on for 1s, off for 1s Fast mode:LED on for 0.5s, off for 0.5s

Display Accuracy

0.1°C

Alarm Temperature

reach 37.4°C

Calibrate Temperature

36.5°C

Display Range

28°C to 42°C

Ambient Temperature

16°C to 32°C (indoor use, no winds)

Response Time

within 2 seconds (standard mode), 1 second (fast mode)

Voltage Range and Display

DC10V-15V, DC12V/2A adapter included in package lower than 10V LED shows DCL,over 15V shows DCH

Power Consumption

<24W

Alarm Way

sound and flashlight, optional alarm to alarm center by network

Working Temperature

-10°C to 55°C


Instructions

1. After installing the thermometer camera and power on, connect to the network (IP wired network / WIFI / optional 4G module wireless)

2. When the network connection is successful, set the thermometer camera through the computer programming tool

3. Mode setting:
301 items : 00 is calibration mode, 01 is standard mode, 02 is the fast mode, the default is 01

4. Temperature calibration:
Use the computer programming tool and black body for calibration

5. When a person enters the detection area of the thermometer camera, the LED displays the currently body temperature, and a“beep”sound prompts.

When the measured temperature reaches 37.4 ° C, the device will prompt five times of ''bi--bi--bi--" sound, and two alarm lights flash, at the same time upload the current temperature, alarm information and images to the management platform software

6. Communication of the alarm center : authorized by the alarm center

7. Image View : use TMS thermometer management platform software, also can use WI-FI hot-spot to view real-time image and temperature through mobile phone APP and laptop computer software (VMS).


Working Status Display


LED Display

Define

Displa''1 to 9''

Self-checking

Displa''Number & ''

Current ambient temperature

Displa''Round in Circl'''

Ambient temperature detection

Displa''H''

Extreme High Temperature

Displa''L''

Extreme Low Temperature

Display''ERR''

Sensor fault

Thermometer camera software 1

Installation



Notes on installation and use

1. When the thermometer camera is installed and fixed, the lens is recommended to be flush with the human face. In the case of wearing a face mask test, the lens should be 1m ± 0.1m away from the human face. If without the mask, the lens should be distanced from the human face 1.2m ± 0.1m;

2. After installation, a detection area should be set up on the ground of the detection area to facilitate personnel standing and a waiting line on the ground to facilitate personnel waiting;

3. When the thermometer camera is installed on a tripod, it is recommended to set a landmark on the ground for each legs, so that it can be used directly in the corresponding position when it is used next time;

4. After the installation, there are three different modes that can be set by professionals : calibration mode, standard mode, fast mode, and the factory default

is standard mode;

5. If the computer and smart phone need to be connected to the device, please make sure the Wi-Fi hot-spot is connected or network cable is connected;

6. When using the standard mode: set a channel to measure the temperature one person by another. When someone is in the temperature measurement area, the people behind need to wait outside the cordon. During the temperature measurement, the personnel cannot follow and walk too closely and need to keep one meter distance, it is recommended to stop for 1-2 seconds during temperature measurement, and then leave after hearing the "Bee--" sound. After the person in front leaves, the person in the back can enter;

7. In the fast mode: personnel can continuously enter the temperature measurement area, but the distance between the personnel needs to be more than 1m, the test speed is 0.5-1.5s / person, the personnel walk slightly slower (walking speed within 0.5m per second) ) You can pass the temperature measurement normally;

8. When people go through the temperature measurement area, please remove the glasses on face;

9. The test temperature of the device is between 16 to 32°C. If it is lower or higher than this ambient temperature range, the temperature measurement error will increase or it may not be used normally.

10. The body temperature detector should be used indoors to avoid the influence of sunlight, rain and wind on the temperature measurement accuracy. If you have to use it outdoors, you need to build a tent that can cover the temperature measurement area;

11. The one who enters the temperature measurement area from a high or low temperature environment, the measurement may not be accurate. It is recommended to wait for 2-3 minutes before the temperature measurement.

Within 10s after the thermometer camera is powered on, which is during the calibration process, there must be no people or other high temperature objects in front of the device, it will affect the measurement accuracy too.


Common Troubleshooting

Troubles

Possible Phenomena

Possible Reason

Treatment

Temperature Inaccurate

LED shows uncertain temperature when testing

Ambient temperature is too low or too high

Test in the indoor or windless environment to ensure the ambient temperature is between 16 °C -32 °C

Always alert or unable to measure temperature

The two warning lights above the device keep flashing

The device is facing an overheated object or the sensor is exposed to direct sunlight

1 Remove the overheated object which in front of the device

2 Avoid the sunlight before the sensor

Device does not respond during the temperature measurement

The device is too far from the human body

Adjust the distance

Device cannot connect to the network

Green light at the end of the network cable is off

Network cable connection failure

Check router, network switch and network cable

Computer programming tool cannot detect the device

Network problem, the device did not get the IP address correctly

Need to enable router DHCP function

Thermometer camera 10-Anxia

Packing List

No.

Item Name

Quantity (PCS)

1

Automatic Thermometer Camera

1

2

Tripod

1

3

Adapter

1

4

32G TF Card (in device already)

1

5

User's Manual

1

6

Certificate of Approval

1


Cautions and Daily Maintenance

  1. Before using the product, be sure to read this manual in detail and operate it correctly in accordance with the usage method of the manual. Do not use it in humid or high temperature environment. Please keep well ventilated and avoid rain or direct sunlight.

  2. When cleaning the equipment, do not use volatile solvents, such as alcohol, benzene, thinner, gaseous organic solvents or water to clean the equipment, so as not to damage the surface coating and equipment damage or damage the equipment; do not work while the equipment is working When spraying alcohol on the device, disinfect it.

  3. It is strictly forbidden to put the product into fire or water to avoid the danger of fire and explosion.

  4. Do not shake, knock, or hit the product vigorously.

  5. Please use the product according to the instructions. Our company will not be responsible for any loss and injury caused by improper use.

Warranty

We provide 12 months warranty since customer received the goods and conformed.

Conditions of free repairing, free spare parts changing or change a new device must without improper use or destruction by users.

During the period of warranty , users should paid for the shipping charge and necessary tariffs when send back.

Thermometer camera 9-Anxia

Hot Tags: thermal & optical bi-spectrum network bullet camera, China thermal & optical bi-spectrum network bullet camera factory, manufacturers, suppliers, best finger oxygen tester, finger monitor oxygen, finger tip monitor, fingertip co2 monitor, hand sanitizer face recognition camera measuring equipment, oxygen meter for your finger

Send Inquiry